BQBYJ - J-100C 80W/90 MG 724
- MSDS: BQBYJ
- Manufacturer: WITCO
- Product Name: J-100C 80W/90 MG 724
- National Stock Number: 9150-00N034718
Product Identification
Product ID:J-100C 80W/90 MG 724
MSDS Date:06/04/1986
FSC:9150
NIIN:00N034718
MSDS Number: BQBYJ
Responsible Party
OILDALE, CA 93388-5446
US
Emergency Phone: 805-393-7110;800-424-9300(CHEMTREC)
Info Phone: 805-393-7110
Cage: 6Z384
Contractor
Telephone: 805-393-7110/800-424-9300(CHEMTREC)
Cage: 1F469
Ingredients
SOLVENT REFINED HEAVY NAPHTHENIC DISTILLATE, PETROLEUM
CAS: 64741-96-4
RTECS: PY8040001
MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-REFINED
CAS: 64741-88-4
RTECS: PY8040501
OSHA PEL 5 MG/M3 (OIL MIST)
ACGIH TLV: 5 MG/M3 (OIL MIST)
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PROLONGED OR REPEATED SKIN CONTACT MAY
CAUSE DERMATITIS (SKIN IRRITATION).
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: IMMEDIATELY FLUSH WITH LARGE QUANTITIES OF WATER FOR AT
LEAST 15 MINUTES AND CALL PHYSICIAN. SKIN: WASH WITH SOAP AND
WATER. INHALATION: REMOVE VICTIM TO FRESH AIR. INGESTION: CONTACT
PHYSICIAN IMMEDIATELY.
Fire Fighting
Flash Point Method:COC
Flash Point:300F,149C
Extinguishing Media:DRY CHEMICAL, WATERSPRAY, CO*2, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. AVOID USE OF WATER. WATER MAY CAUSE FROTHING. WATER MAY BE
INEFFECTIVE. EXPOS MATL MAY BE COOLED W/WATER.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:IN CASE OF SPILL OR LEAK ABSORB ON AN INERT
MATERIAL SUCH AS EARTH, SAND OR VERMICULITE; SWEEP UP AND DISPOSE
OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. IF
SPILLED INTO WATER, REMOVE BULK OF PRODUCT BY SKIMMING.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINERS TIGHTLY CLOSED. AVOID
STRONG OXIDIZERS. ELIMINATE ALL SOURCES OF IGNITION SUCH AS FLAMES
OR SPARKS.
Other Precautions:AVOID PROLONGED OR REPEATED CONTACT WITH SKIN OR
BREATHING OF VAPORS, MISTS OR FUMES.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR WITH ORGANIC
VAPOR CARTRIDGE IF VAPOR CONCENTRATION EXCEEDS PERMISSIBLE EXPOSURE
LIMIT.
Ventilation:LOCAL IF NECESSARY TO MAINTAIN ALLOWABLE PEL OR TLV.
Protective Gloves:OIL RESISTANT GLOVES.
Eye Protection:CHEM WORK GOG/FULL LGTH FACESHLD .
Other Protective Equipment:NONE.
Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
% VOLAT: <.01 @ 25C (WT). SPECIFIC GRAVITY: .99 (H*2O=1). CAS
#64741-88-4 AND 64741-96-4 ARE SEVERELY SOLVENT REFINED (MR.
J.DAVIS, WITCO) 3/5/93 .
Chemical Properties
HCC:V6
Boiling Pt:B.P. Text:>550F,>288C
Vapor Pres:<1 @ 20C
Vapor Density:<.1
Spec Gravity:0.89- (SUPDAT)
Evaporation Rate & Reference:<.01 (H*2O=1)
Solubility in Water:0%
Appearance and Odor:OILY LIQUID, NO OBJECTIONABLE ODOR.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS SUCH AS HYDROGEN PEROXIDE, BROMINE, AND CHROMIC ACID.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE
FROM BURNING. OXIDES OF NITROGEN AND OXIDES OF SULFUR.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.